Three-Phase UPS with Battery Cabinets
Representative TITAN Series installation with external battery cabinets for extended backup applications.
View TITAN SeriesChina-side battery and external cabinet supply/configuration support for existing UPS battery replacement, cabinet replacement or expansion, and new UPS + battery projects. Review lead-acid systems, long-runtime configurations or lithium conversion where technically suitable.
ZYKEVO supports UPS service and maintenance companies, IT and server-room service providers, power solution integrators, and local UPS brands and distributors. Start with the work your customer needs completed.
Keep the existing UPS in service and review the battery system that needs replacing. Old battery quantity alone is not sufficient for selection: confirm the UPS condition, DC arrangement, actual load and backup time. Use the UPS battery replacement checklist to collect the evidence, then review the battery replacement project path.
Review an existing or new external cabinet together with the battery arrangement, breaker, cables, usable space and protection requirements. A larger enclosure or additional batteries do not by themselves confirm that the UPS can support the proposed configuration.
Match the UPS and battery system together using the measured or expected load, required runtime and confirmed DC system. Include charger capacity, cabinet arrangement and installation limits in the configuration review.
Lithium is not an automatic replacement for lead-acid. Review the UPS DC voltage range, charging voltage/current, actual load, required runtime, discharge current capability, and BMS/communication requirements where applicable. Use the lead-acid to lithium upgrade review for retrofit planning, or review high-voltage LiFePO4 battery options for UPS projects.
A UPS battery cabinet or replacement battery enclosure must suit both the battery arrangement and the site. Review these items before settling on the cabinet configuration:
Final cabinet size, electrical arrangement, interfaces and documentation are project-specific and must be confirmed by model. For expansion, review whether the existing cabinet, cables and protection can be reused.
Partial information is acceptable for an initial review. Send what you have; a UPS nameplate, current battery label or cabinet photo can help identify the remaining checks. Do not guess unfamiliar electrical values.
Based on the information available, ZYKEVO can help review or prepare:
This is a project-review starting point, not final engineering approval. Availability, model selection, documentation and the quotation scope remain subject to verified project information and written confirmation.
Certification and shipping documentation are confirmed according to the selected model and destination.
UPS brand, model and rated capacity; DC bus voltage or verified string arrangement; Existing battery chemistry, voltage, Ah and quantity; Measured load and required runtime; Charger condition and available charging current.
No. The selected model, electrical configuration, battery system, documents and destination requirements must be confirmed in writing.
Runtime is reviewed from the measured load, UPS DC system, complete battery configuration, charger, operating conditions and the required backup objective.
OEM label, artwork, packaging and documentation coordination may be available for suitable projects after the model and commercial scope are confirmed.
Field References
Representative installation and integration images support project conversations; model, customer and performance details remain subject to confirmation.

Representative TITAN Series installation with external battery cabinets for extended backup applications.
View TITAN Series
Battery rack arrangement shown as an external battery-system reference.
View UPS Batteries & CabinetsSend the UPS model, DC voltage, load and required runtime. If you are replacing an existing battery system, include the current battery specification or a cabinet photo. Partial information is welcome for an initial review.